The flow control accuracy of large-diameter globe valves is largely limited by the operating torque. A globe valve regulates the flow rate by raising and lowering the disc along the centerline of the seat and is one of the few valve designs suitable for continuous throttling service. As valve size increases, fluid forces rise significantly, making it difficult to achieve proper seating and precise adjustment with a long manual lever. Repeated stem movement can also cause the packing to loosen. By adding a gear reduction mechanism, the operating torque is reduced according to the reduction ratio, allowing the valve to be reliably positioned at the required opening even in large-diameter applications. This series is designed and manufactured in accordance with BS 1873, covering NPS 2–12 and Class 150–900, with each valve pressure-tested in accordance with API 598.
The throttling capability of a globe valve comes from its flow-path design: the medium enters from below the disc and exits above it, distributing the pressure drop evenly across the disc and seat area. Unlike a partially open gate valve, where high-velocity flow is concentrated around the edge of the gate and can cause severe erosion, the globe valve disc moves vertically along the seat centerline. Between 10% and 80% opening, the flow rate is approximately linear with valve position, making the valve suitable for minor flow control applications. The trade-off is higher pressure loss than with gate and ball valves, a longer stem travel, and increasing operating torque as valve size increases.
Most failures of large-diameter globe valves are related to operation. Manual valves are often operated by applying excessive force through an extended lever, subjecting the stem at the backseat and packing areas to additional bending moments. Repeated compression can cause packing relaxation, resulting in high-temperature steam leakage through the packing gland. Operators must also exert force from an unfavorable position. A gear-operated design distributes the operating torque through the gear train according to the reduction ratio. The required handwheel torque can be reduced by approximately 70%, providing stable seating force during closure and allowing the valve to remain at any intermediate opening without springing back.
The gear operator should also be selected according to the service conditions. For high-temperature service, an extended bonnet and flexible graphite packing should be used to keep the packing area away from the process temperature. The gear operator should be provided with dust protection and drainage to prevent rainwater from entering and freezing during winter.
The valve body material is selected according to the medium and temperature. Carbon steel is generally used for water and steam service, chrome-molybdenum steel for high-temperature steam, and stainless steel for corrosive media. Each valve is tested for shell strength and seat tightness in accordance with API 598 prior to shipment, and the test report is supplied with the valve.
Power plants and industrial boiler main steam and extraction steam lines: Gear operation is used for large-diameter, high-pressure steam service requiring precise flow adjustment, reducing operating torque.
Steam lines for turbine drives and process heating: Suitable for continuous throttling and can replace some control valves, reducing system cost.
High-temperature hot water and condensate lines: An extended bonnet with flexible graphite packing keeps the packing area below 200 °C.
Chemical process tower bottoms and reflux lines: Suitable where minor flow adjustments are required and the valve must remain stable at an intermediate opening.
High-temperature oil service in the petrochemical industry: Chrome-molybdenum steel valve bodies with Stellite hardfaced seating surfaces provide resistance to high-temperature erosion.
Operating method: Gear operation is recommended for NPS 4 and above or Class 600 and above, reducing operating torque by approximately 70%. Smaller sizes can be equipped with direct handwheel operation.
Temperature and construction: For media temperatures above 200 °C, select an extended bonnet to keep the packing area below 200 °C and prevent premature packing deterioration.
Disc design: For continuous flow control, select a parabolic or conical disc. For on/off service only, a flat disc may be selected for lower cost.
Material and installation: Carbon steel is generally used for water and steam service, chrome-molybdenum steel for high-temperature steam, and stainless steel for corrosive media. The medium must enter from below the disc, and the flow direction is marked on the side of the valve body.
Q: What happens if a globe valve is installed in the wrong direction?A: A globe valve is designed for the medium to enter from below the disc. If installed in the reverse direction, the medium will continuously act on the top of the disc, which may cause high-frequency stem vibration and fatigue failure, as well as uneven wear and leakage at the seating surfaces. The valve must be installed according to the flow-direction marking on the valve body.
Q: What should I do if the handwheel of a gear-operated globe valve cannot be turned?A: The most common causes are excessive packing-gland compression, water ingress and freezing inside the gear operator, or scale buildup on the seating surfaces. Do not use an extension bar to force the valve open or closed. First loosen the packing gland, clean the gear operator, and inspect the seating surfaces before operating the valve.
Q: Why should a globe valve be equipped with an extended bonnet?A: An extended bonnet moves the packing area away from the high-temperature zone, keeping the packing temperature below 200 °C. This prevents accelerated deterioration and external leakage of flexible graphite packing and also facilitates packing replacement while the system remains pressurized.
The high-pressure steam line at the OOO «THK-YBaT» project site in Russia operates at 3.8 MPa and 420 °C for turbine drives and process heating. The original large-diameter manually operated globe valves had excessive operating torque. Even with long levers, operators found it difficult to adjust the flow accurately, while steam leakage from the packing occurred 12 times per year and resulted in two operator burn injuries.
Flowork supplied 40 NPS 4–10, Class 900 gear-operated globe valves featuring A217 WC6 chrome-molybdenum steel valve bodies, extended bonnets, live-loaded flexible graphite packing, and Stellite No. 6 hardfaced seating surfaces. The valves were equipped with bevel-gear reduction operators, reducing operating torque by approximately 70%. Designed in accordance with API 623 and tested in accordance with API 598, the valves were witnessed by the THK-YBaT inspection
Class150
Gear Operated Globe valve

| NPS | in | 2 | 2 1/2 | 3 | 4 | 5 | 6 | 8 | 10 | 12 |
| d | mm | 51 | 64 | 76 | 102 | 127 | 152 | 203 | 254 | 305 |
| L(RF) | mm | 203 | 216 | 241 | 292 | 356 | 406 | 495 | 622 | 698 |
| L(BW) | mm | 203 | 216 | 241 | 292 | 356 | 406 | 495 | 622 | 698 |
| L(RTJ) | mm | 216 | 229 | 254 | 305 | 369 | 419 | 508 | 635 | 711 |
| d1 | mm | 92 | 105 | 127 | 157 | 186 | 216 | 270 | 324 | 381 |
| d2 | mm | 120.5 | 139.5 | 152.5 | 190.5 | 216 | 241.5 | 298.5 | 362 | 432 |
| D | mm | 152 | 178 | 190 | 229 | 254 | 279 | 343 | 406 | 483 |
| b | mm | 16 | 18 | 19 | 24 | 24 | 26 | 29 | 31 | 32 |
| n-Фd | mm | 4-19 | 4-19 | 4-19 | 8-19 | 8-22 | 8-22 | 8-22 | 12-25 | 12-25 |
| H | mm | 330 | 360 | 390 | 445 | 480 | 520 | 600 | 773 | 880 |
| H1 | mm |
|
|
|
|
| 556 | 658 | 805 | 955 |
| W | mm | 200 | 200 | 250 | 300 | 350 | 350 | 500 | 500 | 550 |
| W1 | mm |
|
|
|
|
| 310 | 310 | 460 | 460 |
Class300
Gear Operated Globe valve

| NPS | in | 2 | 2 1/2 | 3 | 4 | 5 | 6 | 8 | 10 | 12 |
| d | mm | 51 | 64 | 76 | 102 | 127 | 152 | 203 | 254 | 305 |
| L(RF) | mm | 267 | 292 | 318 | 356 | 400 | 444 | 559 | 622 | 711 |
| L(BW) | mm | 267 | 292 | 318 | 356 | 400 | 444 | 559 | 622 | 711 |
| L(RTJ) | mm | 283 | 308 | 333 | 371 | 416 | 460 | 575 | 638 | 727 |
| d1 | mm | 92 | 105 | 127 | 157 | 186 | 216 | 270 | 324 | 381 |
| d2 | mm | 127 | 149 | 168.5 | 200 | 235 | 270 | 330 | 387.5 | 451 |
| D | mm | 165 | 190 | 210 | 254 | 279 | 318 | 381 | 445 | 521 |
| b | mm | 23 | 26 | 29 | 32 | 35 | 37 | 42 | 48 | 51 |
| n-Фd | mm | 8-19 | 8-22 | 8-22 | 8-22 | 8-22 | 12-22 | 12-25 | 16-29 | 16-32 |
| H | mm | 385 | 420 | 440 | 515 | 580 | 660 | 900 | 950 | 1030 |
| H1 | mm |
|
|
|
|
| 690 | 950 | 990 | 1080 |
| W | mm | 250 | 250 | 300 | 350 | 450 | 500 | 500 | 550 | 550 |
| W1 | mm |
|
|
|
|
| 310 | 460 | 460 | 460 |
Class600
Gear Operated Globe valve

| NPS | in | 2 | 2 1/2 | 3 | 4 | 5 | 6 | 8 | 10 | 12 |
| d | mm | 51 | 64 | 76 | 102 | 127 | 152 | 200 | 248 | 298 |
| L(RF) | mm | 292 | 330 | 356 | 432 | 508 | 559 | 660 | 787 | 838 |
| L(BW) | mm | 292 | 330 | 356 | 432 | 508 | 559 | 660 | 787 | 838 |
| L(RTJ) | mm | 295 | 333 | 359 | 435 | 511 | 562 | 664 | 791 | 841 |
| d1 | mm | 92 | 105 | 127 | 157 | 186 | 216 | 270 | 324 | 381 |
| d2 | mm | 127 | 149 | 168.5 | 216 | 267 | 292 | 349 | 432 | 489 |
| D | mm | 165 | 190 | 210 | 273 | 330 | 356 | 419 | 508 | 559 |
| b | mm | 26 | 29 | 32 | 38 | 45 | 48 | 56 | 64 | 67 |
| n-Фd | mm | 8-19 | 8-22 | 8-22 | 8-25 | 8-29 | 12-29 | 12-32 | 16-35 | 20-35 |
| H | mm | 360 | 410 | 465 | 545 | 625 | 785 | 930 |
|
|
| H1 | mm |
|
|
| 575 | 660 | 820 | 960 | 1040 | 1280 |
| W | mm | 250 | 300 | 350 | 400 | 500 | 550 | 650 |
|
|
| W1 | mm |
|
|
| 310 | 310 | 460 | 460 | 610 | 610 |
Class900
Gear Operated Globe valve

| NPS | in | 2 | 2 1/2 | 3 | 4 | 5 | 6 | 8 | 10 |
| d | mm | 47 | 57 | 73 | 98 | 121 | 146 | 190 | 234 |
| L(RF) | mm | 368 | 419 | 381 | 457 | 559 | 610 | 737 | 838 |
| L(BW) | mm | 368 | 419 | 381 | 457 | 559 | 610 | 737 | 838 |
| L(RTJ) | mm | 371 | 422 | 384 | 460 | 562 | 613 | 740 | 841 |
| d1 | mm | 92 | 105 | 127 | 157 | 186 | 216 | 270 | 324 |
| d2 | mm | 165 | 190.5 | 190.5 | 235 | 279.4 | 317.5 | 393.7 | 469.9 |
| D | mm | 216 | 244 | 241 | 292 | 349 | 381 | 470 | 545 |
| b | mm | 38.5 | 41.5 | 38.5 | 44.5 | 51 | 56 | 64 | 70 |
| n-Фd | mm | 8-26 | 8-29 | 8-26 | 8-32 | 8-35 | 12-32 | 12-39 | 16-39 |
| H | mm | 480 | 520 | 564 | 685 | 780 | 950 |
|
|
| H1 | mm |
|
| 630 | 720 | 840 | 1015 | 1100 | 1185 |
| W | mm | 350 | 350 | 400 | 450 | 550 | 650 |
|
|
| W1 | mm |
|
| 310 | 310 | 460 | 460 | 610 | 610 |
Class1500
Gear Operated Globe valve

| NPS | in | 2 | 2 1/2 | 3 | 4 | 5 | 6 | 8 |
| d | mm | 47 | 57 | 70 | 92 | 111 | 136 | 178 |
| L(RF) | mm | 368 | 419 | 470 | 546 | 673 | 705 | 832 |
| L(BW) | mm | 368 | 419 | 470 | 546 | 673 | 705 | 832 |
| L(RTJ) | mm | 371 | 422 | 473 | 549 | 676 | 711 | 841 |
| d1 | mm | 92 | 105 | 127 | 157 | 186 | 216 | 270 |
| d2 | mm | 165 | 190.5 | 203.2 | 241.3 | 292.1 | 317.5 | 393.7 |
| D | mm | 216 | 244 | 267 | 311 | 375 | 394 | 483 |
| b | mm | 38.5 | 41.5 | 48 | 54 | 73.5 | 83 | 92.9 |
| n-Фd | mm | 8-26 | 8-29 | 8-32 | 8-35 | 8-42 | 12-39 | 12-45 |
| H | mm | 592 | 660 | 692 |
|
|
|
|
| H1 | mm |
|
|
| 907 | 950 | 1015 | 1145 |
| W | mm | 350 | 400 | 500 |
|
|
|
|
| W1 | mm |
|
|
| 460 | 610 | 610 | 610 |
API Trim NO.
Table
|
No |
Seat |
Gate、disc 、ball or body |
Stem |
No |
Seat |
Gate、disc 、ball or body |
Stem | |
| 01 | 13Cr | 13Cr | 13Cr | 31 | STELLITE | 321SS | 321SS | |
| 02 | 304SS | 304SS | 304SS | 32 | STELLITE | STELLITE | 321SS | |
| 03 | 310SS | 310SS | 310SS | 33 | 347SS | 347SS | 347SS | |
| 04 | HARD 13Cr | HARD 13Cr | 13Cr | 34 | STELLITE | 347SS | 347SS | |
| 05 | STELLITE | STELLITE | 13Cr | 35 | NICKEL ALLOY | 13Cr | 13Cr | |
| 06 | Cu-Ni | 13Cr | 13Cr | 36 | A105/PTFE | A105+ENP | A105+ENP | |
| 07 | 13Cr | HARD 13Cr | 13Cr | 37 | A105/PTFE | WCB+ENP | A105+ENP | |
| 08 | STELLITE | 13Cr | 13Cr | 38 | 13Cr/PTFE | 13Cr | 13Cr | |
| 09 | Cu-Ni | Cu-Ni | Cu-Ni | 39 | 304SS/PTFE | 304SS | 304SS | |
| 10 | 316SS | 316SS | 316SS | 40 | 316SS/PTFE | 316SS | 316SS | |
| 11 | Cu-Ni | STELLITE | Cu-Ni | 41 | A105/RPTFE | A105+ENP | A105+ENP | |
| 12 | STELLITE | 316SS | 316SS | 42 | A105/RPTFE | WCB+ENP | A105+ENP | |
| 13 | ALLOY 20 | ALLOY 20 | ALLOY 20 | 43 | 13Cr/RPTFE | 13Cr | 13Cr | |
| 14 | STELLITE | ALLOY 20 | ALLOY 20 | 44 | 304SS/RPTFE | 304SS | 304SS | |
| 15 | STELLITE | STELLITE | 304SS | 45 | 316SS/RPTFE | 316SS | 316SS | |
| 16 | STELLITE | STELLITE | 316SS | 46 | A105/NYLON | A105+ENP | A105+ENP | |
| 17 | STELLITE | STELLITE | 347SS | 47 | A105/NYLON | WCB+ENP | A105+ENP | |
| 18 | STELLITE | STELLITE | ALLOY 20 | 48 | A105/NYLON | 304SS | 304SS | |
| 19 | MONEL | MONEL | MONEL | 49 | A105/NYLON | 316SS | 316SS | |
| 20 | BRONZE | BRONZE | 13Cr | 50 | 13Cr/NYLON | 13Cr | 13Cr | |
| 21 | HASTELLOY B | HASTELLOY B | HASTELLOY B | 51 | 304SS/NYLON | 304SS | 304SS | |
| 22 |
| HASTELLOY C | HASTELLOY C | 52 | 316SS/NYLON | 316SS | 316SS | |
| 23 | STELLITE | 304SS | 304SS | 53 | A105/PEEK | A105+ENP | A105+ENP | |
| 24 | 304LSS | 304LSS | 304LSS | 54 | A105/PEEK | WCB+ENP | A105+ENP | |
| 25 | STELLITE | 304LSS | 304LSS | 55 | 13Cr/PEEK | 13Cr | 13Cr | |
| 26 | STELLITE | STELLITE | 304LSS | 56 | 304SS/PEEK | 304SS | 304SS | |
| 27 | 316LSS | 316LSS | 316LSS | 57 | 316SS/PEEK | 316SS | 316SS | |
| 28 | STELLITE | 316LSS | 316LSS |
|
|
|
|
|
| 29 | STELLITE | STELLITE | 316LSS |
|
|
| ||
| 30 | 321SS | 321SS | 321SS |
|
|
|
| |
Note:please indicate it directly in the
order for the internal part’smaterial uncovered in the table
A lug type check valve sits between wafer and flanged designs: it has the same short face-to-face length as a wafer valve, but incorporates threaded lugs that allow it to be installed between two pipe flanges and removed from one side without disturbing the piping on the other side. This makes it particularly suitable for space-constrained pipe racks, line ends, and check valve locations on vertical piping, where maintenance can be reduced from cutting the pipe to simply removing the bolts. This series is designed and manufactured in accordance with API 594, covering NPS 2–24, Class 150–300, with dimensions in accordance with ASME B16.10 and ASME B16.5. Each valve is pressure tested in accordance with API 598.
Low emission gate valves are designed for pipelines in refining and chemical plants where strict requirements apply to fugitive emissions of volatile organic compounds (VOCs). By improving the stem packing system and adopting a live-loaded packing gland, these valves control fugitive emissions within certified limits. Face-to-face dimensions comply with ANSI B16.10, flange dimensions with B16.5, and butt-weld end dimensions with B16.25. The valves are designed and manufactured in accordance with API 600, pressure-tested in accordance with API 598, and fugitive-emission-tested in accordance with ISO 15848-1. The product range covers NPS 2–24 and Class 150–2500, with body materials including WCB, WC6, CF8M, CN7M, LCB, and LCC.
Resilient-seated concentric butterfly valves achieve sealing through the interference fit between the disc and the rubber seat. The stem passes through the geometric center of the disc, and a 90-degree rotation completes the opening or closing operation. This design offers a compact face-to-face dimension and low overall weight.
Face-to-face dimensions comply with ANSI B16.10, flange dimensions with ANSI B16.5, and butt-welding ends with ANSI B16.25. Design and manufacture are in accordance with API 609, and pressure testing is performed in accordance with API 598. The product range covers NPS 2–24 and Class 150–300. Available body materials include WCB, CF8M, LCB, C95800, and others.
Corporate Mission: Create Value for Clients, Create Opportunities for Staff, Create Efficiency for Corporate, Create wealth for Society.Quality+Service=Satisfaction.