Gear Operated Globe Valve

Our valves utilize cutting-edge technology, undergo rigorous quality control, ensuring outstanding performance and durability.

  1. Home
  2. »
  3. Product
  4. »
  5. Gear Operated Globe Valve

Gear Operated Globe Valve

The flow control accuracy of large-diameter globe valves is largely limited by the operating torque. A globe valve regulates the flow rate by raising and lowering the disc along the centerline of the seat and is one of the few valve designs suitable for continuous throttling service. As valve size increases, fluid forces rise significantly, making it difficult to achieve proper seating and precise adjustment with a long manual lever. Repeated stem movement can also cause the packing to loosen. By adding a gear reduction mechanism, the operating torque is reduced according to the reduction ratio, allowing the valve to be reliably positioned at the required opening even in large-diameter applications. This series is designed and manufactured in accordance with BS 1873, covering NPS 2–12 and Class 150–900, with each valve pressure-tested in accordance with API 598.

Product Description

The throttling capability of a globe valve comes from its flow-path design: the medium enters from below the disc and exits above it, distributing the pressure drop evenly across the disc and seat area. Unlike a partially open gate valve, where high-velocity flow is concentrated around the edge of the gate and can cause severe erosion, the globe valve disc moves vertically along the seat centerline. Between 10% and 80% opening, the flow rate is approximately linear with valve position, making the valve suitable for minor flow control applications. The trade-off is higher pressure loss than with gate and ball valves, a longer stem travel, and increasing operating torque as valve size increases.

Most failures of large-diameter globe valves are related to operation. Manual valves are often operated by applying excessive force through an extended lever, subjecting the stem at the backseat and packing areas to additional bending moments. Repeated compression can cause packing relaxation, resulting in high-temperature steam leakage through the packing gland. Operators must also exert force from an unfavorable position. A gear-operated design distributes the operating torque through the gear train according to the reduction ratio. The required handwheel torque can be reduced by approximately 70%, providing stable seating force during closure and allowing the valve to remain at any intermediate opening without springing back.

The gear operator should also be selected according to the service conditions. For high-temperature service, an extended bonnet and flexible graphite packing should be used to keep the packing area away from the process temperature. The gear operator should be provided with dust protection and drainage to prevent rainwater from entering and freezing during winter.

The valve body material is selected according to the medium and temperature. Carbon steel is generally used for water and steam service, chrome-molybdenum steel for high-temperature steam, and stainless steel for corrosive media. Each valve is tested for shell strength and seat tightness in accordance with API 598 prior to shipment, and the test report is supplied with the valve.

Applications

Power plants and industrial boiler main steam and extraction steam lines: Gear operation is used for large-diameter, high-pressure steam service requiring precise flow adjustment, reducing operating torque.

Steam lines for turbine drives and process heating: Suitable for continuous throttling and can replace some control valves, reducing system cost.

High-temperature hot water and condensate lines: An extended bonnet with flexible graphite packing keeps the packing area below 200 °C.

Chemical process tower bottoms and reflux lines: Suitable where minor flow adjustments are required and the valve must remain stable at an intermediate opening.

High-temperature oil service in the petrochemical industry: Chrome-molybdenum steel valve bodies with Stellite hardfaced seating surfaces provide resistance to high-temperature erosion.

Selection Guide

Operating method: Gear operation is recommended for NPS 4 and above or Class 600 and above, reducing operating torque by approximately 70%. Smaller sizes can be equipped with direct handwheel operation.

Temperature and construction: For media temperatures above 200 °C, select an extended bonnet to keep the packing area below 200 °C and prevent premature packing deterioration.

Disc design: For continuous flow control, select a parabolic or conical disc. For on/off service only, a flat disc may be selected for lower cost.

Material and installation: Carbon steel is generally used for water and steam service, chrome-molybdenum steel for high-temperature steam, and stainless steel for corrosive media. The medium must enter from below the disc, and the flow direction is marked on the side of the valve body.

Frequently Asked Questions

Q: What happens if a globe valve is installed in the wrong direction?A: A globe valve is designed for the medium to enter from below the disc. If installed in the reverse direction, the medium will continuously act on the top of the disc, which may cause high-frequency stem vibration and fatigue failure, as well as uneven wear and leakage at the seating surfaces. The valve must be installed according to the flow-direction marking on the valve body.

Q: What should I do if the handwheel of a gear-operated globe valve cannot be turned?A: The most common causes are excessive packing-gland compression, water ingress and freezing inside the gear operator, or scale buildup on the seating surfaces. Do not use an extension bar to force the valve open or closed. First loosen the packing gland, clean the gear operator, and inspect the seating surfaces before operating the valve.

Q: Why should a globe valve be equipped with an extended bonnet?A: An extended bonnet moves the packing area away from the high-temperature zone, keeping the packing temperature below 200 °C. This prevents accelerated deterioration and external leakage of flexible graphite packing and also facilitates packing replacement while the system remains pressurized.

Project Case

The high-pressure steam line at the OOO «THK-YBaT» project site in Russia operates at 3.8 MPa and 420 °C for turbine drives and process heating. The original large-diameter manually operated globe valves had excessive operating torque. Even with long levers, operators found it difficult to adjust the flow accurately, while steam leakage from the packing occurred 12 times per year and resulted in two operator burn injuries.

Flowork supplied 40 NPS 4–10, Class 900 gear-operated globe valves featuring A217 WC6 chrome-molybdenum steel valve bodies, extended bonnets, live-loaded flexible graphite packing, and Stellite No. 6 hardfaced seating surfaces. The valves were equipped with bevel-gear reduction operators, reducing operating torque by approximately 70%. Designed in accordance with API 623 and tested in accordance with API 598, the valves were witnessed by the THK-YBaT inspection

Class150 
Gear Operated Globe valve

NPS

in

2

2 1/2

3

4

5

6

8

10

12

d

mm

51

64

76

102

127

152

203

254

305

L(RF)

mm

203

216

241

292

356

406

495

622

698

L(BW)

mm

203

216

241

292

356

406

495

622

698

L(RTJ)

mm

216

229

254

305

369

419

508

635

711

d1

mm

92

105

127

157

186

216

270

324

381

d2

mm

120.5

139.5

152.5

190.5

216

241.5

298.5

362

432

D

mm

152

178

190

229

254

279

343

406

483

b

mm

16

18

19

24

24

26

29

31

32

n-Фd

mm

4-19

4-19

4-19

8-19

8-22

8-22

8-22

12-25

12-25

H

mm

330

360

390

445

480

520

600

773

880

H1

mm

 

 

 

 

 

556

658

805

955

W

mm

200

200

250

300

350

350

500

500

550

W1

mm

 

 

 

 

 

310

310

460

460

Class300 
Gear Operated Globe valve

NPS

in

2

2 1/2

3

4

5

6

8

10

12

d

mm

51

64

76

102

127

152

203

254

305

L(RF)

mm

267

292

318

356

400

444

559

622

711

L(BW)

mm

267

292

318

356

400

444

559

622

711

L(RTJ)

mm

283

308

333

371

416

460

575

638

727

d1

mm

92

105

127

157

186

216

270

324

381

d2

mm

127

149

168.5

200

235

270

330

387.5

451

D

mm

165

190

210

254

279

318

381

445

521

b

mm

23

26

29

32

35

37

42

48

51

n-Фd

mm

8-19

8-22

8-22

8-22

8-22

12-22

12-25

16-29

16-32

H

mm

385

420

440

515

580

660

900

950

1030

H1

mm

 

 

 

 

 

690

950

990

1080

W

mm

250

250

300

350

450

500

500

550

550

W1

mm

 

 

 

 

 

310

460

460

460

Class600 
Gear Operated Globe valve

NPS

in

2

2 1/2

3

4

5

6

8

10

12

d

mm

51

64

76

102

127

152

200

248

298

L(RF)

mm

292

330

356

432

508

559

660

787

838

L(BW)

mm

292

330

356

432

508

559

660

787

838

L(RTJ)

mm

295

333

359

435

511

562

664

791

841

d1

mm

92

105

127

157

186

216

270

324

381

d2

mm

127

149

168.5

216

267

292

349

432

489

D

mm

165

190

210

273

330

356

419

508

559

b

mm

26

29

32

38

45

48

56

64

67

n-Фd

mm

8-19

8-22

8-22

8-25

8-29

12-29

12-32

16-35

20-35

H

mm

360

410

465

545

625

785

930

 

 

H1

mm

 

 

 

575

660

820

960

1040

1280

W

mm

250

300

350

400

500

550

650

 

 

W1

mm

 

 

 

310

310

460

460

610

610

Class900 
Gear Operated Globe valve

NPS

in

2

2 1/2

3

4

5

6

8

10

d

mm

47

57

73

98

121

146

190

234

L(RF)

mm

368

419

381

457

559

610

737

838

L(BW)

mm

368

419

381

457

559

610

737

838

L(RTJ)

mm

371

422

384

460

562

613

740

841

d1

mm

92

105

127

157

186

216

270

324

d2

mm

165

190.5

190.5

235

279.4

317.5

393.7

469.9

D

mm

216

244

241

292

349

381

470

545

b

mm

38.5

41.5

38.5

44.5

51

56

64

70

n-Фd

mm

8-26

8-29

8-26

8-32

8-35

12-32

12-39

16-39

H

mm

480

520

564

685

780

950

 

 

H1

mm

 

 

630

720

840

1015

1100

1185

W

mm

350

350

400

450

550

650

 

 

W1

mm

 

 

310

310

460

460

610

610

Class1500 
Gear Operated Globe valve

NPS

in

2

2 1/2

3

4

5

6

8

d

mm

47

57

70

92

111

136

178

L(RF)

mm

368

419

470

546

673

705

832

L(BW)

mm

368

419

470

546

673

705

832

L(RTJ)

mm

371

422

473

549

676

711

841

d1

mm

92

105

127

157

186

216

270

d2

mm

165

190.5

203.2

241.3

292.1

317.5

393.7

D

mm

216

244

267

311

375

394

483

b

mm

38.5

41.5

48

54

73.5

83

92.9

n-Фd

mm

8-26

8-29

8-32

8-35

8-42

12-39

12-45

H

mm

592

660

692

 

 

 

 

H1

mm

 

 

 

907

950

1015

1145

W

mm

350

400

500

 

 

 

 

W1

mm

 

 

 

460

610

610

610

API Trim NO.
Table

 

No
  of internal parts

 

Seat
  ring or body

 

Gate、disc 、ball or body

 

Stem

 

No
  of internal parts

 

Seat
  ring or body

 

Gate、disc 、ball or body

 

Stem

01

13Cr

13Cr

13Cr

31

STELLITE

321SS

321SS

02

304SS

304SS

304SS

32

STELLITE

STELLITE

321SS

03

310SS

310SS

310SS

33

347SS

347SS

347SS

04

HARD 13Cr

HARD 13Cr

13Cr

34

STELLITE

347SS

347SS

05

STELLITE

STELLITE

13Cr

35

NICKEL ALLOY

13Cr

13Cr

06

Cu-Ni

13Cr

13Cr

36

A105/PTFE

A105+ENP

A105+ENP

07

13Cr

HARD 13Cr

13Cr

37

A105/PTFE

WCB+ENP

A105+ENP

08

STELLITE

13Cr

13Cr

38

13Cr/PTFE

13Cr

13Cr

09

Cu-Ni

Cu-Ni

Cu-Ni

39

304SS/PTFE

304SS

304SS

10

316SS

316SS

316SS

40

316SS/PTFE

316SS

316SS

11

Cu-Ni

STELLITE

Cu-Ni

41

A105/RPTFE

A105+ENP

A105+ENP

12

STELLITE

316SS

316SS

42

A105/RPTFE

WCB+ENP

A105+ENP

13

ALLOY 20

ALLOY 20

ALLOY 20

43

13Cr/RPTFE

13Cr

13Cr

14

STELLITE

ALLOY 20

ALLOY 20

44

304SS/RPTFE

304SS

304SS

15

STELLITE

STELLITE

304SS

45

316SS/RPTFE

316SS

316SS

16

STELLITE

STELLITE

316SS

46

A105/NYLON

A105+ENP

A105+ENP

17

STELLITE

STELLITE

347SS

47

A105/NYLON

WCB+ENP

A105+ENP

18

STELLITE

STELLITE

ALLOY 20

48

A105/NYLON

304SS

304SS

19

MONEL

MONEL

MONEL

49

A105/NYLON

316SS

316SS

20

BRONZE

BRONZE

13Cr

50

13Cr/NYLON

13Cr

13Cr

21

HASTELLOY B

HASTELLOY B

HASTELLOY B

51

304SS/NYLON

304SS

304SS

22

 

HASTELLOY C

HASTELLOY C

52

316SS/NYLON

316SS

316SS

23

STELLITE

304SS

304SS

53

A105/PEEK

A105+ENP

A105+ENP

24

304LSS

304LSS

304LSS

54

A105/PEEK

WCB+ENP

A105+ENP

25

STELLITE

304LSS

304LSS

55

13Cr/PEEK

13Cr

13Cr

26

STELLITE

STELLITE

304LSS

56

304SS/PEEK

304SS

304SS

27

316LSS

316LSS

316LSS

57

316SS/PEEK

316SS

316SS

28

STELLITE

316LSS

316LSS

 

 

 

 

 

29

STELLITE

STELLITE

316LSS

 

 

 

30

321SS

321SS

321SS

 

 

 

 

Note:please indicate it directly in the
order for the internal part’smaterial uncovered in the table

POPULAR PRODUCTS

Our industrial valves are designed for optimal performance and reliability across a wide range of applications.

A lug type check valve sits between wafer and flanged designs: it has the same short face-to-face length as a wafer valve, but incorporates threaded lugs that allow it to be installed between two pipe flanges and removed from one side without disturbing the piping on the other side. This makes it particularly suitable for space-constrained pipe racks, line ends, and check valve locations on vertical piping, where maintenance can be reduced from cutting the pipe to simply removing the bolts. This series is designed and manufactured in accordance with API 594, covering NPS 2–24, Class 150–300, with dimensions in accordance with ASME B16.10 and ASME B16.5. Each valve is pressure tested in accordance with API 598.

Low emission gate valves are designed for pipelines in refining and chemical plants where strict requirements apply to fugitive emissions of volatile organic compounds (VOCs). By improving the stem packing system and adopting a live-loaded packing gland, these valves control fugitive emissions within certified limits. Face-to-face dimensions comply with ANSI B16.10, flange dimensions with B16.5, and butt-weld end dimensions with B16.25. The valves are designed and manufactured in accordance with API 600, pressure-tested in accordance with API 598, and fugitive-emission-tested in accordance with ISO 15848-1. The product range covers NPS 2–24 and Class 150–2500, with body materials including WCB, WC6, CF8M, CN7M, LCB, and LCC.

Resilient-seated concentric butterfly valves achieve sealing through the interference fit between the disc and the rubber seat. The stem passes through the geometric center of the disc, and a 90-degree rotation completes the opening or closing operation. This design offers a compact face-to-face dimension and low overall weight.

Face-to-face dimensions comply with ANSI B16.10, flange dimensions with ANSI B16.5, and butt-welding ends with ANSI B16.25. Design and manufacture are in accordance with API 609, and pressure testing is performed in accordance with API 598. The product range covers NPS 2–24 and Class 150–300. Available body materials include WCB, CF8M, LCB, C95800, and others.